An EEG recording setup using the 10-10 system of electrode placement. EEG is the gold standard diagnostic procedure to confirm epilepsy.The sensitivity of a routine EEG to detect interictal epileptiform discharges at epilepsy centers has been reported to be in the range of 29–55%. [8]
The electrodes are normally placed about an inch apart, and the resistance recorded varies according to the emotional state of the subject. Galvanic skin potential (GSP) refers to the voltage measured between two electrodes without any externally applied current. It is measured by connecting the electrodes to a voltage amplifier.
The ERN is a sharp negative going signal which begins about the same time an incorrect motor response begins, (response locked event-related potential), and typically peaks from 80 to 150 milliseconds (ms) after the erroneous response begins (or 40–80 ms after the onset of electromyographic activity).
An electrode introduced into the brain of a living animal will detect electrical activity that is generated by the neurons adjacent to the electrode tip. If the electrode is a microelectrode, with a tip size of about 1 micrometre, the electrode will usually detect the activity of at most one neuron.
Silicon electrodes are alloy electrodes doped with silicon and an insulating glass cover layer. Silicon technology provides better mechanical stiffness and is a good supporting carrier to allow for multiple recording sites on a single electrode. [31] Tungsten electrodes are very rugged and provide very stable recordings. This allows ...
The electric current from the electrode stimulates whatever function that site in the brain is responsible for, in essence telling the surgeon or examiner what a specific locale in the brain does. [6] Electrodes are usually made of stainless steel or platinum-iridium embedded in a silastic material, and are usually circular with diameters of 2 ...
fNIRS electrode locations can be defined using a variety of layouts, including names and locations that are specified by the International 10–20 system as well as other layouts that are specifically optimized to maintain a consistent 30mm distance between each location. In addition to the standard positions of electrodes, short separation ...
The first meaning is usually intended in literature that deals with rats or mice, while the second meaning is usually intended in studies of human EEG recorded using electrodes glued to the scalp. In general, it is not safe to assume that observations of "theta" in the human EEG have any relationship to the "hippocampal theta rhythm".