An air handling unit used for the heating and cooling air: (1) supply air (2) fan section (3) vibration isolator (4) cooling coil (5) filter (6) mixed air duct. Air supply to a building is generally performed by an air handling unit. The process may include filtering, heating, cooling, humidification, or dehumidification, all of which consume ...
A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.
A reversing valve removed from an HVAC heat pump for replacement. A reversing valve is a type of valve and is a component in a heat pump, that changes the direction of refrigerant flow. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a residence or facility to ...
An exhaust air heat pump (EAHP) extracts heat from the exhaust air of a building and transfers the heat to the supply air, hot tap water and/or hydronic heating system (underfloor heating, radiators). [27] [28] This requires at least mechanical exhaust but mechanical supply is optional; see mechanical ventilation. This type of heat pump ...
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and climate control - for example, in the case of ...
The condenser is the hot side of an air conditioner or heat pump. Condensers are heat exchangers, and can transfer heat to air or to an intermediate fluid (such as water or an aqueous solution of ethylene glycol ) to carry heat to a distant sink, such as ground (earth sink), a body of water, or air (as with cooling towers).