Ads
related to: how does mixing valve work on a boiler pump air conditioner 3 ton
Search results
Results From The WOW.Com Content Network
Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.
Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]
A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...
Brass-bodied float valve. An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with ...
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and climate control - for example, in the case of ...
Mixing of liquids occurs frequently in process engineering. The nature of liquids to blend determines the equipment used. Single-phase blending tends to involve low-shear, high-flow mixers to cause liquid engulfment, while multi-phase mixing generally requires the use of high-shear, low-flow mixers to create droplets of one liquid in laminar, turbulent or transitional flow regimes, depending ...
High flow rates (from 14 to 51 US gallons per minute (53 to 193 L/min) at 45 pounds per square inch (3.1 bar)) Temperature stability; Point-of-Use. These are single Outlet Thermostatic Mixing Valves, often called "thermostatic faucets", "thermostat taps" or "thermostat valves".