When.com Web Search

  1. Ads

    related to: tempering valve location on furnace heater

Search results

  1. Results From The WOW.Com Content Network
  2. Thermostatic mixing valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_mixing_valve

    Tempering valves for use on hot water heat distribution systems; High flow rates suitable for use in under floor (radiant) heating applications; Allows water to be stored at a higher temperature; Group Control. These provide a uniform distribution temperature for all hot water outlets in a household. Designed for multi-point applications

  3. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    The program features include time schedules, set points, controllers, logic, timers, trend logs, and alarms. The unit controllers typically have analog and digital inputs that allow measurement of the variable (temperature, humidity, or pressure) and analog and digital outputs for control of the transport medium (hot/cold water and/or steam ...

  4. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    The result of automatically mixing hot and cold water via a tempering valve is referred to as "tempered water". [13] A tempering valve mixes enough cold water with the hot water from the heater to keep the outgoing water temperature fixed at a more moderate temperature, often set to 50 °C (122 °F). Without a tempering valve, reduction of the ...

  5. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    A safety valve allows water to escape from the system when pressure becomes too high, and a valve can open to replenish water from the normal water supply if the pressure drops too low. Sealed systems offer an alternative to open-vent systems, in which steam can escape from the system, and gets replaced from the building's water supply via a ...

  6. Thermostat - Wikipedia

    en.wikipedia.org/wiki/Thermostat

    A thermostatic mixing valve uses a wax pellet to control the mixing of hot and cold water. A common application is to permit operation of an electric water heater at a temperature hot enough to kill Legionella bacteria (above 60 °C, 140 °F), while the output of the valve produces water that is cool enough to not immediately scald (49 °C, 120 ...

  7. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    In general, valves nearest to the boiler should vent the slowest, and valves furthest from the boiler should vent the fastest. [citation needed] Ideally, steam should reach each valve and close each and every valve at the same time, so that the system can work at maximal efficiency; this condition is known as a "balanced" system. [citation needed]

  8. Heat trap - Wikipedia

    en.wikipedia.org/wiki/Heat_trap

    Heat traps are valves or loops of pipe on the cold water inlet and hot water outlet of water heaters. The heat traps allow cold water to flow into the water heater tank, but prevent unwanted natural convection and heated water to flow out of the tank. [1] [2] Newer water heaters have built-in heat traps.

  9. Thermostatic radiator valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_radiator_valve

    A thermostatic radiator valve on position 2 (15–17 °C) Installed thermostatic radiator valve with the adjustment wheel removed A thermostatic radiator valve (TRV) is a self-regulating valve fitted to hot water heating system radiator, to control the temperature of a room by changing the flow of hot water to the radiator.