When.com Web Search

  1. Ad

    related to: synchronize generator to grid board

Search results

  1. Results From The WOW.Com Content Network
  2. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    In an alternating current (AC) electric power system, synchronization is the process of matching the frequency, phase and voltage of a generator or other source to an electrical grid in order to transfer power. If two unconnected segments of a grid are to be connected to each other, they cannot safely exchange AC power until they are synchronized.

  3. Synchroscope - Wikipedia

    en.wikipedia.org/wiki/Synchroscope

    If the generator is turning at a lower frequency than the grid, the synchroscope pointer rotates continually in the direction (usually counterclockwise) marked "slow" or "lag" on the dial to indicate that the generator is running slower than, or lagging behind, the grid. If the generator is running faster than the grid, the pointer rotates ...

  4. Synchronverter - Wikipedia

    en.wikipedia.org/wiki/Synchronverter

    Figure 5. Compact control structure for a grid-connected inverter. Since a synchronous generator is inherently synchronized with the grid, it is possible to integrate the synchronization function into the power controller without synchronization unit. [17] This results in a compact control unit, as shown in the figure 4.

  5. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    With the SSS clutch retrofit, the existing turbine setup is largely reused. Here, the turbine uses its existing fuel source to start and sync to the grid, which is when the SSS clutch disconnects the turbine and generator. The generator thus uses grid energy to keep spinning, to provide leading or lagging reactive power as needed.

  6. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid.

  7. Wide area synchronous grid - Wikipedia

    en.wikipedia.org/wiki/Wide_area_synchronous_grid

    Inertia in a synchronous grid is stored energy that a grid has available which can provide extra power for up to a few seconds to maintain the grid frequency. Historically, this was provided only by the angular momentum of the generators, and gave the control circuits time to adjust their output to variations in loads, and sudden generator or ...

  8. Synchronization - Wikipedia

    en.wikipedia.org/wiki/Synchronization

    In movie and television production it is necessary to synchronize video frames from multiple cameras. In addition to enabling basic editing, synchronization can also be used for 3D reconstruction [31] In electric power systems, alternator synchronization is required when multiple generators are connected to an electrical grid.

  9. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    A 200 kW Caterpillar diesel generator set in a sound attenuated enclosure used as an emergency backup at a sewage treatment substation in Atlanta, United States. A diesel generator (DG) (also known as a diesel GenSet) is the combination of a diesel engine with an electric generator (often an alternator) to generate electrical energy. [1]