When.com Web Search

  1. Ad

    related to: 3 phase wiring colours

Search results

  1. Results From The WOW.Com Content Network
  2. IEC 60446 - Wikipedia

    en.wikipedia.org/wiki/IEC_60446

    British Standard BS 7671:2001 Amendment No 2:2004 adopted the IEC 60446 colours for fixed wiring in the United Kingdom , with the extension that grey can also be used for line conductors, such that three colours are available for three-phase installations. This extension is expected to be adopted across Europe and may even find its way into a ...

  3. Electrical wiring in the United Kingdom - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_the...

    Blue, previously used as a phase colour, is now the colour for neutral. Black, which was previously used for neutral, now indicates a phase. Household wiring does not usually use three-phase supplies and the clash only occurs in three-phase systems. Wiring to the old standard can be detected by use of a red wire.

  4. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  6. Electrical code - Wikipedia

    en.wikipedia.org/wiki/Electrical_code

    Installation wiring: (section 3.8.1) recommended for single phase [d] recommended for multiphase While light blue is prohibited from use for active function, dark blue is recommended for L3. usually used for "Switched Line" [19] To designate any phase, the below colours are prohibited: [d] [e] (before 1980) (before 1966)

  7. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    Since some wiring may be reversed, which would make motors turn backward, many machines on construction sites feature a phase swap plug that allows the L2 and L3 phase pins to be swapped, thereby reversing the phase sequence. Three-phase electric motors do not need the neutral wire to function, so that there is also a red four pin variant (3 ...

  8. BS 7671 - Wikipedia

    en.wikipedia.org/wiki/BS_7671

    The single-phase colours of red phase and black neutral are replaced by brown phase and blue neutral. These colours have been used in appliance flexible cables since 1969. The cable core colours are described in IEC 60304 (1982-01), Standard colours for insulation for low- frequency cables and wires. The three-phase phase colours are brown ...

  9. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The neutral conductor of a 3-phase, 4-wire system and the middle conductor of a 2- phase, 3-wire system must have at least 2 separate and distinct earth connections with a minimum of 2 different earth electrodes to have a satisfactory earth resistance; The earth electrodes must be interconnected to reduce earth resistance