  2. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    Under no load, when no current flows through the secondary coils, V nl is given by the ideal model, where V S = V P *N S /N P. Looking at the equivalent circuit and neglecting the shunt components, as is a reasonable approximation, one can refer all resistance and reactance to the secondary side and clearly see that the secondary voltage at no ...

  3. Transformer - Wikipedia

    en.wikipedia.org/wiki/Transformer

    An ideal transformer is linear, lossless and perfectly coupled. Perfect coupling implies infinitely high core magnetic permeability and winding inductance and zero net magnetomotive force (i.e. i p n p − i s n s = 0). [3] [c] Ideal transformer connected with source V P on primary and load impedance Z L on secondary, where 0 < Z L < ∞.

  4. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of the circuit.

  5. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...

  6. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...

  7. 24 Affordable Camper Alternatives for Escaping the Crowds - AOL

    www.aol.com/25-affordable-camper-alternatives...

    Hitting the open road in your own RV can easily cost upward of $100,000 before you even fill up the tank. If that seems steep, consider some affordable alternatives. 24 Affordable Camper ...

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    The equivalent power rating of the autotransformer is lower than the actual load power rating. It is calculated by: load VA × (|Vin – Vout|)/Vin. [2] For example, an auto transformer that adapts a 1000 VA load rated at 120 volts to a 240 volt supply has an equivalent rating of at least: 1,000 VA (240 V – 120 V) / 240 V = 500 VA.

  9. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    Capacitor banks are used in substations to balance the lagging current draw from inductive loads (such as motors, transformers, and some industrial equipment) with their reactive load. [46] Additional capacitor capacity may be needed if dispersed generation (such as small diesel generators, rooftop photovoltaic solar panels , or wind turbines ...