Ads
related to: how does varian truebeam work in excel formula worksheet for practice
Search results
Results From The WOW.Com Content Network
Varian Medical Systems is an American radiation oncology treatments and software maker based in Palo Alto, California. Their medical devices include linear accelerators (LINACs) and software for treating cancer and other medical conditions with radiotherapy , radiosurgery , proton therapy , and brachytherapy .
Varian Associates was one of the first high-tech companies in Silicon Valley.It was founded in 1948 by Russell H. and Sigurd F. Varian, William Webster Hansen, and Edward Ginzton to sell the klystron, the first vacuum tube which could amplify electromagnetic waves at microwave frequencies, and other electromagnetic equipment.
Both spatial domain methods, and frequency (spectral) domain methods are available for the numerical solution of the discretized master equation. Upon discretization into a grid, (using various centralized difference, Crank–Nicolson method, FFT-BPM etc.) and field values rearranged in a causal fashion, the field evolution is computed through iteration, along the propagation direction.
Varian, Inc. was one of the largest manufacturers of scientific instruments for the scientific industry. [1] They had offerings over a broad range of chemical analysis equipment, with a particular focus on Information Rich Detection [ clarification needed ] and Vacuum technology.
Varian Associates, an electronics company which split up into three companies in 1999: Varian Medical Systems, a manufacturer of medical equipment; Varian, Inc., a manufacturer of scientific instruments, now part of Agilent Technologies; Varian Semiconductor, a supplier of equipment for semiconductor manufacturers, now part of Applied Materials
M 2 is useful because it reflects how well a collimated laser beam can be focused to a small spot, or how well a divergent laser source can be collimated. It is a better guide to beam quality than Gaussian appearance because there are many cases in which a beam can look Gaussian, yet have an M 2 value far from unity. [1]
Using other definitions of beam width does not work. In principle, one could use a single measurement at the waist to obtain the waist diameter, a single measurement in the far field to obtain the divergence, and then use these to calculate the BPP. The procedure above gives a more accurate result in practice, however.
The equations below assume a beam with a circular cross-section at all values of z; this can be seen by noting that a single transverse dimension, r, appears.Beams with elliptical cross-sections, or with waists at different positions in z for the two transverse dimensions (astigmatic beams) can also be described as Gaussian beams, but with distinct values of w 0 and of the z = 0 location for ...