  1. Results From The WOW.Com Content Network
  2. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    The system is called reverse acting if it is necessary to apply negative corrective action. For instance, if the valve in the flow loop was 100–0% valve opening for 0–100% control output – meaning that the controller action has to be reversed. Some process control schemes and final control elements require this reverse action.

  3. Ziegler–Nichols method - Wikipedia

    en.wikipedia.org/wiki/Ziegler–Nichols_method

    The Ziegler–Nichols tuning method is a heuristic method of tuning a PID controller.It was developed by John G. Ziegler and Nathaniel B. Nichols.It is performed by setting the I (integral) and D (derivative) gains to zero.

  4. Setpoint (control system) - Wikipedia

    en.wikipedia.org/wiki/Setpoint_(control_system)

    A setpoint can be any physical quantity or parameter that a control system seeks to regulate, such as temperature, pressure, flow rate, position, speed, or any other measurable attribute. In the context of PID controller , the setpoint represents the reference or goal for the controlled process variable.

  5. Integral windup - Wikipedia

    en.wikipedia.org/wiki/Integral_windup

    Within modern distributed control systems and programmable logic controllers, it is much easier to prevent integral windup by either limiting the controller output, limiting the integral to produce feasible output, [5] or by using external reset feedback, which is a means of feeding back the selected output to the integral circuit of all ...

  6. Computed torque control - Wikipedia

    en.wikipedia.org/wiki/Computed_torque_control

    () ¨ + (, ˙) ˙ + = where is the state vector of joint variables that describe the system, () is the inertia matrix, (, ˙) ˙ is the vector Coriolis and centrifugal torques, () are the torques caused by gravity and is the vector of joint torque inputs.

  7. Lead–lag compensator - Wikipedia

    en.wikipedia.org/wiki/Lead–lag_compensator

    Given the control plant, desired specifications can be achieved using compensators. I, P, PI, PD, and PID, are optimizing controllers which are used to improve system parameters (such as reducing steady state error, reducing resonant peak, improving system response by reducing rise time). All these operations can be done by compensators as well ...

  8. Control system - Wikipedia

    en.wikipedia.org/wiki/Control_system

    The control action is the switching on/off of the boiler, but the controlled variable should be the building temperature, but is not because this is open-loop control of the boiler, which does not give closed-loop control of the temperature. In closed loop control, the control action from the controller is dependent on the process output.

  9. Open-loop controller - Wikipedia

    en.wikipedia.org/wiki/Open-loop_controller

    A feed back control system, such as a PID controller, can be improved by combining the feedback (or closed-loop control) of a PID controller with feed-forward (or open-loop) control. Knowledge about the system (such as the desired acceleration and inertia) can be fed forward and combined with the PID output to improve the overall system ...