  1. Results From The WOW.Com Content Network
  2. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    The type 15 plug and socket has 3 round pins of 4 mm diameter, plus 2 flat pins (for L2 and L3). It is designed for three phase applications and is rated at 10 A, 250 V/440 V. The socket will also accept types 11 and 12 plugs, and the Europlug. The type 25 plug and socket has 3 rectangular pins, 4 mm x 5 mm, plus 2 flat pins (for L2 and L3).

  3. Circuit total limitation - Wikipedia

    en.wikipedia.org/wiki/Circuit_total_limitation

    The 2008 code did away with the previous 42 circuit limitation on panelboards. [3] One can now order panelboards with as many as 84 circuit places, and a corresponding ampacity rating. If a panelboard with a sufficient number of breaker positions is installed in the first place, the need for non-CTL breakers should be eliminated.

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.

  5. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    IEC 60309 (formerly IEC 309 and CEE 17, also published by CENELEC as EN 60309) is a series of international standards from the International Electrotechnical Commission (IEC) for "plugs, socket-outlets and couplers for industrial purposes".

  6. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    3–5 times rated current I n, e.g. a nominally 10 A device will trip at 30–50 A C 5–10 times I n: D 10–14 times I n: K 8–12 times I n. For the protection of loads that cause frequent short-duration (approximately 400 ms to 2 s) current peaks in normal operation Z 2–3 times I n for durations on the order of tens of seconds.

  7. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Even when unmarked, it is generally easy to identify this type of system, because the B phase (circuits #3 and #4) and every third circuit afterwards will be either a three-pole breaker or a blank. Current practice is to give separate services for single-phase and three-phase loads, e.g., 120 V split-phase (lighting etc.) and 240 V to 600 V ...