A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...
Such devices may be found in the form of either a circuit breaker, known as an earth-leakage circuit breaker (ELCB), or built into a socket (aka receptacle). Voltage-operated ELCBs can still be found in the wild, though these largely fell out of favour after the invention of the current-sensing based RCD (aka GFCI) technology.
For example, my rather small house has a 42 pole panelboard (only about 20 poles installed, though; 240 volt appliances get 2-pole circruit breakers), 200 ampere main circuit breaker, with no GFCI circuit breakers mounted and only one AFCI panel mounted circuit breaker for the bedroom receptacles; there are GFCI receptacles for bathroom ...
Breakers for protections against earth faults too small to trip an over-current device: Residual-current device (RCD), or residual-current circuit breaker (RCCB) — detects current imbalance, but does not provide over-current protection. In the United States and Canada, these are called ground fault circuit interrupters (GFCI).
To provide supplementary protection against high-impedance faults it is common to recommend a residual-current device (RCD) also known as a residual current circuit breaker (RCCB), ground fault circuit interrupter (GFCI), or residual current operated circuit-breaker with integral over-current protection (RCBO), which will cut off the supply of ...
Ground-fault circuit interrupter (GFCI) protection is required on receptacles in wet locations and locations where there exists an easy path for fault current to travel to earth. This includes all receptacles intended to service kitchen counter surfaces, crawl spaces at or below grade level, basements, garages and accessory buildings, bathrooms ...
Although the OSHA regulations require either a ground conductor program or a ground fault circuit interrupter (GFCI), these two devices provide protection in very different ways. A GFCI disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor.
A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.