Street elbows are available with bend angles of 90°, 45°, and 22.5°. They can be used in many plumbing applications, including water supply, drainage, sewers, vents, central vacuum systems, compressed air and gas lines, heating and air conditioning, sump pump drains, and other locations where plumbing fittings would be used to join sections of pipe.
Electrical metallic tubing (EMT), sometimes called thin-wall, is commonly used instead of galvanized rigid conduit (GRC), as it is less costly and lighter than GRC. EMT itself is not threaded, but can be used with threaded fittings that clamp to it. Lengths of conduit are connected to each other and to equipment with clamp-type fittings.
This naming convention applies to other plumbing elbows, such as: - "88 degree elbow" = 92 degrees on a protractor. Visualise bending the left end of the pipe up 88 degrees. Now turn the piece of pipe around so the horizontal piece of pipe is in line with the zero degrees line on the protractor. The protractor will read 92 degrees.
The standard for Nominal Pipe Size (often abbreviated NPS, which should not be confused with the abbreviation NPS for the straight thread form standard) is loosely related to the inside diameter of Schedule 40 series of sizes. Because of the pipe wall thickness of Schedule pipe, the actual diameter of the NPT threads is larger than the Nominal ...
The hot and neutral blades are angled at 45° from vertical and 90° to each other, unlike NEMA 10 devices (where the angles are 30° and 60° respectively), also the plug is slightly smaller than a NEMA 10 and larger than ordinary 5-15P plugs. The ground pin is round, like those on straight-blade NEMA grounding devices.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
Rigid may be required for certain areas and additionally, vapor-lock fittings may be required in areas where a fire or explosion hazard is present (such as gas stations, chemical factories, grain silos, etc.) PVC can be used where wire is run underground or where concrete will be poured. A duct bank is usually made of multiple PVC conduits ...
The conduit methods were known to be of better quality, but cost significantly more than K&T. [2] In 1909, flexible armored cable cost about twice as much as K&T, and conduit cost about three times the price of K&T. [6] Knob and tube wiring persisted since it allowed owners to wire a building for electricity at lower cost.