When.com Web Search

  1. Ads

    related to: fail indeterminate valve in pipe size pdf download file

Search results

  1. Results From The WOW.Com Content Network
  2. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    When the pilot valve reaches set pressure it opens and releases the pressure from the dome. The piston is then free to open and the main valve exhausts the system fluid. The control pilot opens either to the main valve exhaust pipe or to atmosphere. Snap acting At set pressure the valve snaps to full lift.

  3. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Double pipe heat exchanger Fixed straight tubes heat exchanger: U-shaped tubes heat exchanger Spiral heat exchanger Covered gas vent Curved gas vent Air filter: Funnel or tundish: Steam trap: Viewing glass Pressure reducing valve: Valve: Gate valve: Control valve: Manual valve Check valve: Needle valve: Butterfly valve: Diaphragm valve: Ball ...

  4. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  5. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  6. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure , temperature , and liquid level.

  7. Hydraulic shock - Wikipedia

    en.wikipedia.org/wiki/Water_hammer

    To keep water hammer low, pipe-sizing charts for some applications recommend flow velocity at or below 1.5 m/s (4.9 ft/s). Fit slowly closing valves. Toilet fill valves are available in a quiet fill type that closes quietly. Non-slam check valves do not rely on fluid flow to close and will do so before the water flow reaches significant velocity.