When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Shutdown valve - Wikipedia

    en.wikipedia.org/wiki/Shutdown_valve

    A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.

  3. High-integrity pressure protection system - Wikipedia

    en.wikipedia.org/wiki/High-integrity_pressure...

    A high-integrity pressure protection system (HIPPS) is a type of safety instrumented system (SIS) designed to prevent over-pressurization of a plant, such as a chemical plant or oil refinery. The HIPPS will shut off the source of the high pressure before the design pressure of the system is exceeded, thus preventing loss of containment through ...

  4. Process plant shutdown systems - Wikipedia

    en.wikipedia.org/wiki/Process_plant_shutdown_systems

    A depressurization system comprises an actuated valve and a restriction orifice. The BDV valve is normally held in the closed position but opens on demand or on failure of the actuator. A restriction orifice (RO) downstream of the BDV is sized to achieve the desired blowdown rate. A locked-open valve may be located downstream of the orifice.

  5. List of abbreviations in oil and gas exploration and production

    en.wikipedia.org/wiki/List_of_abbreviations_in...

    BTO/C – break to open/close (valve torque) BTU – British thermal units; BTU – Board of Trade Unit (1 kWh) (historical) BU – bottom up; BUL – bottom-up lag; BUR – build-up rate; BVO – ball valve operator; bwd – barrels of water per day (often used in reference to oil production) bwipd – barrels of water injected per day

  6. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.

  7. Partial stroke testing - Wikipedia

    en.wikipedia.org/wiki/Partial_stroke_testing

    λ D = The dangerous failure rate of the safety function. TI FC = The full closure interval, i.e. how often the valve must be full closed for testing. TI PST = The partial stroke test interval. The proof test coverage is a measure of how effective the partial stroke test is and the higher the PTC the greater the effect of the test.

  8. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...

  9. Butterfly valve - Wikipedia

    en.wikipedia.org/wiki/Butterfly_valve

    Unlike a ball valve, the disc is always present within the flow, so it induces a pressure drop, even when open. A butterfly valve is from a family of valves called quarter-turn valves. In operation, the valve is fully open or closed when the disc is rotated a quarter turn. The "butterfly" is a metal disc mounted on a rod. When the valve is ...