When.com Web Search

  1. Ads

    related to: wilkins 600xl prv 4 pipe size table

Search results

  1. Results From The WOW.Com Content Network
  2. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    The downstream side is the pipe or open air where the PORV directs its exhaust. The outlet pipe is typically larger than the inlet. 2 in × 3 in (51 mm × 76 mm), 3 in × 4 in (76 mm × 102 mm), 4 in × 6 in (100 mm × 150 mm), 6 in × 8 in (150 mm × 200 mm), 8 in × 10 in (200 mm × 250 mm) are some common sizes.

  3. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...

  4. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  5. Iron pipe size - Wikipedia

    en.wikipedia.org/wiki/Iron_pipe_size

    During the IPS period, pipes were cast in halves and welded together, and pipe sizes referred to the inside diameters. [1] The inside diameters under IPS were roughly the same as the more modern Ductile Iron Pipe Standard (DIPS) and Nominal Pipe Size (NPS) Standards, and some of the wall thicknesses were also retained with a different ...

  6. Standard dimension ratio - Wikipedia

    en.wikipedia.org/wiki/Standard_dimension_ratio

    Standard dimension ratio (SDR) is a method of rating a pipe's durability against pressure. The standard dimension ratio describes the correlation between the pipe dimension and the thickness of the pipe wall. [1] Common nominations are SDR11, SDR17, SDR26 and SDR35. Pipes with a lower SDR can withstand higher pressures.

  7. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  8. Specified minimum yield strength - Wikipedia

    en.wikipedia.org/wiki/Specified_Minimum_Yield...

    It is an indication of the minimum stress a pipe may experience that will cause plastic (permanent) deformation. The SMYS is required to determine the maximum allowable operating pressure (MAOP) of a pipeline, as determined by Barlow's Formula which is P = (2 * S * T)/(OD * SF), where P is pressure, OD is the pipe’s outside diameter, S is the ...

  9. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    Reduced pressure zone device connected to a fire hydrant. A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination.