When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Deadweight tester - Wikipedia

    en.wikipedia.org/wiki/Deadweight_tester

    A dead weight tester (DWT) is a calibration standard method that uses a piston cylinder on which a load is placed to make an equilibrium with an applied pressure underneath the piston. Deadweight testers are secondary standards which means that the pressure measured by a deadweight tester is defined through other quantities: length, mass and ...

  3. Highway Addressable Remote Transducer Protocol - Wikipedia

    en.wikipedia.org/wiki/Highway_Addressable_Remote...

    The HART Communication Protocol (Highway Addressable Remote Transducer) is a hybrid analog+digital industrial automation open protocol. Its most notable advantage is that it can communicate over legacy 4–20 mA analog instrumentation current loops, sharing the pair of wires used by the analog-only host systems.

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    As an example, a manual process may be used for calibration of a pressure gauge. The procedure requires multiple steps, [12] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the ...

  5. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    A diagram which shows the interconnection of process equipment and the instrumentation used to control the process. In the process industry, a standard set of symbols is used to prepare drawings of processes. The instrument symbols used in these drawings are generally based on International Society of Automation (ISA) Standard S5.1

  6. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Pressure sensors can alternatively be called pressure transducers, pressure transmitters, pressure senders, pressure indicators, piezometers and manometers, among other names. Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area.

  7. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60172 Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires; IEC 60183 Guidance for the selection of high-voltage A.C. cable systems; IEC 60188 High-pressure mercury vapour lamps – Performance specifications; IEC 60189 Low-frequency cables and wires with PVC insulation and PVC sheath

  8. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.

  9. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]