Search results
Results From The WOW.Com Content Network
Arcing horns protecting bushings on a distribution transformer. Arcing horns form a spark gap across the insulator with a lower breakdown voltage than the air path along the insulator surface, so an overvoltage will cause the air to break down and the arc to form between the arcing horns, diverting it away from the surface of the insulator. [3]
A fuse is a common type of circuit breaker that involves direct effect of Joule-overheating. A fuse is always placed in series with the path of current it will affect. Fuses usually consist of a thin strand of wire of definite-material. When more that the rated current flows through the fuse, the wire melts and breaks the circuit.
Utility, industrial, and commercial power systems have additional protection devices to detect relatively small but undesired currents escaping to ground. In residential wiring, electrical regulations may now require arc-fault circuit interrupters on building wiring circuits, to detect small arcs before they cause damage or a fire. For example ...
A high-resistance connection (HRC) is a hazard that results from loose or poor connections in traditional electrical accessories and switchgear which can cause heat to develop, capable of starting a fire. [1] Glowing connections occur when relatively high current exists in a relatively large resistance object. Heat comes from power dissipation ...
In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...
Many fire horn systems were wired to fire pull boxes that were located around a town, and this would "blast out" a code in respect to that box's location. For example, pull box number 233, when pulled, would trigger the fire horn to sound two blasts, followed by a pause, followed by three blasts, followed by a pause, followed by three more blasts.
An arc flash is the light and heat produced from an electric arc supplied with sufficient electrical energy to cause substantial damage, harm, fire, or injury. Electrical arcs experience negative incremental resistance , which causes the electrical resistance to decrease as the arc temperature increases.
A black match is a type of fuse consisting of cotton string coated with a dried slurry of black powder and glue. This acts as a simple pass-fire, and was used to fire ancient cannons. They are used today in fireworks construction. A quick match or piped match is a type of black powder fuse that burns very quickly, some hundreds of feet per ...