  2. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    In that case, the wire is not tri-rated. According to UL 758, the maximum operating temperature of tri-rated cable is 105 °C. British Standard BS 6231 requires only a maximum operating temperature of 90 °C for continuous use. UL and CSA give tri-rated cable a voltage rating of 600 V, while it is rated at 1000 V in the BS 6231 standard.

  3. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.

  5. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    Conductors installed so that air can freely move over them can be rated to carry more current than conductors run inside a conduit or buried underground. High ambient temperature may reduce the current rating of a conductor. Cables run in wet or oily locations may carry a lower temperature rating than in a dry installation. A lower rating will ...

  6. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.

  7. Electrical cable - Wikipedia

    en.wikipedia.org/wiki/Electrical_cable

    An electrical cable is an assembly of one or more wires running side by side or bundled, which is used as an electrical conductor to carry electric current. Electrical cables are used to connect two or more devices, enabling the transfer of electrical signals, power, or both from one device to the other. Physically, an electrical cable is an ...

  8. SY control cable - Wikipedia

    en.wikipedia.org/wiki/SY_control_cable

    An SY control cable is a flexible instrumentation electrical cable designed for measuring, control or regulation in the field of process automation. [1] It is a flexible multicore cable, with (class 5) [which?] copper conductors and a galvanised steel wire braid (GSWB) for mechanical protection.

  9. powerCon - Wikipedia

    en.wikipedia.org/wiki/PowerCon

    The main advantages of the powerCON are high current capacity in a small space (smaller than an IEC connector and double the current-carrying capacity) and locking action. The main disadvantages are cost and reliance on a single vendor.