  1. Results From The WOW.Com Content Network
  2. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    (E.g. two 14 AWG wires have about the same cross-sectional area as a single 11 AWG wire.) This doubles the conductance. When the diameter of a solid round wire is doubled, the AWG will decrease by 6. (E.g. 1 mm diameter wire is ≈18 AWG, 2 mm diameter wire is ≈12 AWG, and 4 mm diameter wire is ≈6 AWG.)

  3. Manganin - Wikipedia

    en.wikipedia.org/wiki/Manganin

    Several Manganin resistors served as the legal standard for the ohm in the United ... AWG ohms per cm ... 0.0405 14 .00211 0.0644 16 .00336 0.102 18 .00535 ...

  4. Talk:American wire gauge - Wikipedia

    en.wikipedia.org/wiki/Talk:American_wire_gauge

    Finally, in the reference, this table is supposed to be showing how these rules of thumb can be applied to a variety of other AWGs based on 10 AWG having 1 ohm per 1000 ft. That should be explained here, AND, 1 mΩ/ft should have been used as the starting point for 10 AWG rather than the 1.6 mΩ/ft used in this table.

  5. Speaker wire - Wikipedia

    en.wikipedia.org/wiki/Speaker_wire

    Ordinary lamp cord has an inductance of 0.1–0.2 μH/ft, likewise for shielded cord, [6] so a run of up to about 10 feet (20 total feet of conductor) will have less than 1% inductive loss in the audible range (10 ft * 0.2 μH/ft = 2.0 μH, which is at or below the proximate threshold of 2 μH given above). Some premium speaker cables have ...

  6. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  7. Category 5 cable - Wikipedia

    en.wikipedia.org/wiki/Category_5_cable

    The maximum length for a cable segment is 100 meters (330 ft) per TIA/EIA 568-5-A. [31] If longer runs are required, the use of active hardware such as a repeater or switch is necessary. [ 32 ] [ 33 ] The specifications for 10BASE-T networking specify a 100-meter length between active devices. [ 34 ]

  8. Twin-lead - Wikipedia

    en.wikipedia.org/wiki/Twin-lead

    The characteristic impedance of twin lead is a function of the insulating material and its thickness, and the wire diameter and its spacing; in the most common type, 300 Ω twin-lead ribbon cable, the wire is usually AWG 20 or 22 (0.52 or 0.33 mm²), about 7.5 millimetres (0.30 in) apart.

  9. ANSI/TIA-568 - Wikipedia

    en.wikipedia.org/wiki/ANSI/TIA-568

    ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).