When.com Web Search

  1. Ads

    related to: how to calculate motor current value

Search results

  1. Results From The WOW.Com Content Network
  2. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    Now, if this motor is fed with current of 2 A and assuming that back-EMF is exactly 2 V, it is rotating at 7200 rpm and the mechanical power is 4 W, and the force on rotor is = N or 0.0053 N. The torque on shaft is 0.0053 N⋅m at 2 A because of the assumed radius of the rotor (exactly 1 m).

  3. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The field produced by a single-phase winding can provide energy to a motor already rotating, but without auxiliary mechanisms the motor will not accelerate from a stop. A rotating magnetic field of steady amplitude requires that all three phase currents be equal in magnitude, and accurately displaced one-third of a cycle in phase.

  5. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase induction motor has a simple design, inherently high starting torque and high efficiency. Such motors are applied in industry for many applications. A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three ...

  6. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    The base value should only be a magnitude, while the per-unit value is a phasor. The phase angles of complex power, voltage, current, impedance, etc., are not affected by the conversion to per unit values. The purpose of using a per-unit system is to simplify conversion between different transformers.

  7. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    [7] [8] The test can be repeated for different values of voltage to ensure the values obtained are consistent. As the current through the stator may exceed the rated current, the test should be conducted quickly. [4] By using the parameters found by this test, the motor circle diagram can be constructed. [9]

  1. Ad

    related to: how to calculate motor current value