Search results
Results From The WOW.Com Content Network
Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.
Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.
A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.
A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.
Gate valves are used to shut off the flow of liquids rather than for flow regulation, which is frequently done with a globe valve. When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low flow resistance. [1] The size of the open flow path generally varies in a nonlinear manner as the gate is moved.
The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...
A lifeguard shortage has scrambled the hours and schedules at many L.A.-area public pools. Here's how to find a different pool — or become a lifeguard and earn a little summer cash.
In this way, applying power to the "open damper" terminal causes the motor to run until the damper is open while applying power at the "close damper" terminal causes the motor to run until the damper is closed. The motor is commonly powered from the same 24 volt AC power source that is used for the rest of the control system. This allows the ...