When.com Web Search

  1. Ads

    related to: what is a floating circuit panel

Search results

  1. Results From The WOW.Com Content Network
  2. Floating ground - Wikipedia

    en.wikipedia.org/wiki/Floating_ground

    A floating ground is a reference point for electrical potential in a circuit which is galvanically isolated from actual earth ground. Most electrical circuits have a ground which is electrically connected to the Earth, hence the name "ground". The ground is said to be floating when this connection does not exist. [1]

  3. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    If circuit 2 is an audio system and circuit 1 ... wire at the utility ground bonding point at the service panel. ... have a floating ground connected ...

  4. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  5. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    The test often reveals problems that occurred during assembly, such as defective components, improper component placement, and insulator defects that may cause inadvertent shorting or grounding to chassis, in turn, compromising electrical circuit quality and product safety. [2]

  6. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.

  7. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    If an open-circuit is detected (e.g., due to a broken weld on the NGR), the monitoring device will sense voltage through the sensing resistor and trip the breaker. Without a sensing resistor, the system could continue to operate without ground protection (since an open circuit condition would mask the ground fault) and transient overvoltages ...