Ads
related to: r134a refrigerant pressure enthalpy chart
Search results
Results From The WOW.Com Content Network
This is a list of refrigerants, sorted by their ASHRAE-designated numbers, ... pressure, absolute kPa PCC: R-10: Carbon tetrachloride (Tetrachloromethane) CCl 4:
Solubility of water in HFC-134a at 25 °C 0.11% by weight Flammability Limits in Air at 1 atm None Autoignition temperature 770 °C (1,420 °F) Ozone depletion potential: 0 Halocarbon Global Warming Potential (HGWP) (For CFC-11, HGWP = 1) 0.28 Global Warming Potential (GWP) (100 yr ITH. For CO 2, GWP = 1) 1,200
1,1,1,2-Tetrafluoroethane (also known as norflurane (), R-134a, Klea 134a, Freon 134a, Forane 134a, Genetron 134a, Green Gas, Florasol 134a, Suva 134a, HFA-134a, or HFC-134a) is a hydrofluorocarbon (HFC) and haloalkane refrigerant with thermodynamic properties similar to R-12 (dichlorodifluoromethane) but with insignificant ozone depletion potential and a lower 100-year global warming ...
Promoted as climate-friendly substitute for R-134a and R-410A, but still with high climate impact. Has excellent heat transfer and pressure drop performance, both in condensation and vaporisation. [66] It has an atmospheric lifetime of nearly 5 years. [67] Currently used in residential and commercial air-conditioners and heat pumps. R-134a HFC ...
An enthalpy–entropy chart, also known as the H–S chart or Mollier diagram, plots the total heat against entropy, [1] describing the enthalpy of a thermodynamic system. [2] A typical chart covers a pressure range of 0.01–1000 bar , and temperatures up to 800 degrees Celsius . [ 3 ]
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
Molar enthalpy of zinc above 298.15 K and at 1 atm pressure, showing discontinuities at the melting and boiling points. The Δ H °m of zinc is 7323 J/mol, and the Δ H °v is 115 330 J/mol. Enthalpy change for a chemical reaction
At the start of the thermodynamic cycle the refrigerant enters the compressor as a low pressure and low temperature vapor. In heat pumps, this refrigerant is typically R32 refrigerant or R290 refrigerant. Then the pressure is increased and the refrigerant leaves as a higher temperature and higher pressure superheated gas.
Ad
related to: r134a refrigerant pressure enthalpy chart