    Under no load, when no current flows through the secondary coils, V nl is given by the ideal model, where V S = V P *N S /N P. Looking at the equivalent circuit and neglecting the shunt components, as is a reasonable approximation, one can refer all resistance and reactance to the secondary side and clearly see that the secondary voltage at no ...

  3. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of the circuit.

  4. Load regulation - Wikipedia

    en.wikipedia.org/wiki/Load_regulation

    is the voltage at maximum load. The maximum load is the one that draws the greatest current, i.e. the lowest specified load resistance (never short circuit); is the voltage at minimum load. The minimum load is the one that draws the least current, i.e. the highest specified load resistance (possibly open circuit for some types of linear ...

  5. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...

  6. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    A shunt reactor is typically connected to an end of a long transmission line or a weak system to prevent overvoltage under light load (Ferranti effect); [10] passive sources of reactive power (e. g., shunt or series capacitors). shunt capacitors are used in power systems since the 1910s and are popular due to low cost and relative ease of ...

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    The equivalent power rating of the autotransformer is lower than the actual load power rating. It is calculated by: load VA × (|Vin – Vout|)/Vin. [2] For example, an auto transformer that adapts a 1000 VA load rated at 120 volts to a 240 volt supply has an equivalent rating of at least: 1,000 VA (240 V – 120 V) / 240 V = 500 VA.

  8. Amorphous metal transformer - Wikipedia

    en.wikipedia.org/wiki/Amorphous_metal_transformer

    An amorphous metal transformer (AMT) is a type of energy efficient transformer found on electric grids. [1] The magnetic core of this transformer is made with a ferromagnetic amorphous metal . The typical material ( Metglas ) is an alloy of iron with boron , silicon , and phosphorus in the form of thin (e.g. 25 μm) foils rapidly cooled from melt.

  9. Isolation transformer - Wikipedia

    en.wikipedia.org/wiki/Isolation_transformer

    In electronics testing and servicing, an isolation transformer is a 1:1 (under load) power transformer used for safety. Without it, exposed live metal in a device under test is at a hazardous voltage relative to grounded objects such as a heating radiator or oscilloscope ground lead (a particular hazard with some old vacuum-tube equipment with ...