Under no load, when no current flows through the secondary coils, V nl is given by the ideal model, where V S = V P *N S /N P. Looking at the equivalent circuit and neglecting the shunt components, as is a reasonable approximation, one can refer all resistance and reactance to the secondary side and clearly see that the secondary voltage at no ...
An amorphous metal transformer (AMT) is a type of energy efficient transformer found on electric grids. [1] The magnetic core of this transformer is made with a ferromagnetic amorphous metal . The typical material ( Metglas ) is an alloy of iron with boron , silicon , and phosphorus in the form of thin (e.g. 25 μm) foils rapidly cooled from melt.
The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of the circuit.
A "transformer bank", widely used in North America: three single-phase transformers connected to make a 3-phase transformer. The low-voltage secondary windings are attached to three or four terminals on the transformer's side. In North American residences and small businesses, the secondary is often the split-phase 120/240-volt system. The 240 ...
Usually utilization category is mentioned in most of the switch gear, with the above contactor stating to be used under AC1 - resistive load & AC3 for motor usage. In electrical engineering utilization categories are defined by IEC standards [1] and indicate the type of electrical load and duty cycle of the loads to ease selection of contactors ...
A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. [ 1 ] [ 2 ] During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator ...
The ferroresonant transformer, ferroresonant regulator or constant-voltage transformer is a type of saturating transformer used as a voltage regulator. These transformers use a tank circuit composed of a high-voltage resonant winding and a capacitor to produce a nearly constant average output voltage with a varying input current or varying load.
passive (either permanently connected or switched) sinks of reactive power (e.g., shunt reactors that are similar to transformers in construction, with a single winding and iron core [9]). A shunt reactor is typically connected to an end of a long transmission line or a weak system to prevent overvoltage under light load (Ferranti effect); [10]