When.com Web Search

  1. Ads

    related to: window r-value calculator for air conditioning units for residential homes

Search results

  1. Results From The WOW.Com Content Network
  2. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    The units of an R-value (see below) are usually not explicitly stated, and so it is important to determine from context which units are being used: an R-value expressed in I-P (inch-pound) units [13] is about 5.68 times larger than when expressed in SI units, [14] so that, for example, a window that is R-2 in I-P units has an RSI of 0.35 (since ...

  3. Insulated glazing - Wikipedia

    en.wikipedia.org/wiki/Insulated_glazing

    Vacuum Insulating Glass (VIG) units result in R-values as high as R-15 (center of glass). Combining a VIG unit with another glass pane and warm edge spacer result in R-18 (center of glass) or more depending upon the low-e coating(s). Double VIG units with warm edge spacer reach R-25 (center of glass) or more depending upon low-e coatings and ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  5. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    The packaged terminal air conditioner (PTAC), through-the-wall, and window air conditioners are similar. These units are installed on a window frame or on a wall opening. The unit usually has an internal partition separating its indoor and outdoor sides, which contain the unit's condenser and evaporator, respectively.

  6. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  7. Window insulation - Wikipedia

    en.wikipedia.org/wiki/Window_insulation

    The U-factor of a window can often be found on the rating label of the window. Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal ...