Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
When the box is activated by turning a knob or pulling a hook, a spring-loaded wheel turns, tapping out a pulsed electrical signal corresponding to the box's number. [1] A receiver at fire headquarters announces the alarm through flashing lights or tones, or via a pen recorder, and the box number is matched to a list of box locations.
The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.
Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.
Some smoke alarms use a combination of the 2; usually using the 9V battery as an extra power source in the event of an outage. Commercial smoke detectors issue a signal to a fire alarm control panel as part of a fire alarm system. Usually, an individual commercial smoke detector unit does not issue an alarm; some, however, have built-in sounders.
Under the name "Thorn/Autocall", the company produced the TFX-series addressable panels and C-series conventional panels, which were rebrands of the Silent Knight SK-series conventional panels of the time. An Autocall C-2000 panel. This panel was the 2 zone variant of the C-series conventional fire alarm panels released by Autocall in the late ...
Many fire doors do not lock, to allow building occupants to move within the building to find an exit easily. On the other hand, security doors may close, latch, and lock, to prevent passage. Other designs are used to secure sliding or overhead doors similarly, holding them open until a signal to release the doors to close automatically.
The standard fire alarm sound used in most of North America. Coding refers to the pattern or tones a notification appliance sounds in and is controlled either by the panel or by setting jumpers or DIP switches on the notification appliances. The majority of audible notification appliances installed prior to 1996 produced a steady sound for ...