The specific equipment involved may be called an Energy Recovery Ventilator, also commonly referred to simply as an ERV. An ERV is a type of air-to-air heat exchanger that transfers latent heat as well as sensible heat. Because both temperature and moisture are transferred, ERVs are described as total enthalpic devices. In contrast, a heat ...
Air streams are mixed to save energy and improve energy efficiency by partially recirculating conditioned air.. The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1]
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
Some HRSGs include supplemental, or duct firing. These additional burners provide additional energy to the HRSG, which produces more steam and hence increases the output of the steam turbine. Generally, duct firing provides electrical output at lower capital cost. It is therefore often utilized for peaking operations.
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
[2] The terminal reheat system cools the air in the air handling unit down to the lowest possible needed temperature within its zone of spaces. This supplies a comfortable quality to the space, but wastes energy. The mixed air system has two air streams, typically one for the coldest and one for the hottest needed air temperature in the zone.
The duct flange normally has 3/4" bolts at 6" nominal; spacing. Duct flange angle thickness needs to be designed for duct plate tensile stresses, as flanges will bend. 5/16" or 3/8" angle thicknesses are common. See above photo of round duct elbows, transitions, and stiffeners. The duct elbow radius is from 1 1/2 to 2 times the duct diameter.
HVAC turning vanes are sheet metal devices inside of mechanical ductwork used to smoothly direct air inside a duct where there is a change in direction, by reducing resistance and turbulence. See also