The International Electrotechnical Commission publishes the 60079 series of standards [2] which defines a system for classification of locations, as well as categorizing and testing of equipment designed for use in hazardous locations, known as "Ex equipment". IEC 60079-10-1 covers classification of explosive gas atmospheres, and IEC 60079-10-2 ...
Below is a list of NEMA enclosure types; these types are further defined in NEMA 250- Enclosures for Electrical Equipment. Each type specifies characteristics of an enclosure, but not, for example, a specific enclosure size. Note that higher numbers do not include the lower-numbered tests. For example, types 3, 4 and 6 are intended for outdoor ...
Maximum experimental safe gap (MESG) is a standardized measurement of how easily a gas flame will pass through a narrow gap bordered by heat-absorbing metal. MESG is used to classify flammable gases for the design and/or selection of electrical equipment in hazardous areas, and flame arrestor devices. [1]
Intrinsic safety (IS) is a protection technique for safe operation of electrical equipment in hazardous areas by limiting the energy, electrical and thermal, available for ignition. In signal and control circuits that can operate with low currents and voltages, the intrinsic safety approach simplifies circuits and reduces installation cost over ...
The aim of Directive 2014/34/EU is to allow the free trade of ‘ATEX’ equipment and protective systems within the EU by removing the need for separate testing and documentation for each member state. The regulations apply to all equipment intended for use in explosive atmospheres, whether electrical or mechanical, including protective systems.
The preparation and installation of electrical equipment in explosive atmospheres within the water industry Ex10: The inspection, test and maintenance of electrical equipment in explosive atmospheres within the water industry Ex11: The competency requirements for EN 13463 Parts 1, 5 and 6 for operatives working with mechanical equipment Ex12
However, equipment of this class is common in some 120 V countries, and in much of the 230 V developing world, whether permitted officially or not. These appliances do not have their chassis connected to electrical earth. In many countries the plug of a class 0 equipment is such that it cannot be inserted to grounded outlet like Schuko. The ...
In 1994 were established Electrical Safety Foundation International non-profit organization dedicated exclusively to promoting electrical safety at home and in the workplace. [ 3 ] Standard 29 CFR 1910.269 – for electric power generation, transmission, and distribution, contained comprehensive regulations and addressed control of hazardous ...