The use of the vernier scale is shown on a vernier caliper which measures the internal and the external diameters of an object. The vernier scale is constructed so that it is spaced at a constant fraction of the fixed main scale. So for a vernier with a constant of 0.1, each mark on the vernier is spaced 9/10 of those on the main scale.
In the science of measurement, the least count of a measuring instrument is the smallest value in the measured quantity that can be resolved on the instrument's scale. [1] The least count is related to the precision of an instrument; an instrument that can measure smaller changes in a value relative to another instrument, has a smaller "least ...
A vernier caliper does not easily lose its calibration, but a sharp impact or accidental damage to the measuring surface in the caliper jaw can be significant enough to displace zero. [29] Digital calipers have zero set buttons, for quick recalibration. Vernier, dial and digital calipers can be used with accessories that extend their usefulness.
Case 1 is an empty tank at the charging pressure P c (gauge). The total volume of the tank is V t. Case 2 is a tank in use, with the air pressure at pressure P (gauge) and a water volume of V. Referring to the diagram on the right, a pressure tank is generally pressurized when empty with a "charging pressure" P c, which is usually about 2 psi ...
Vernier micrometer reading 5.783 ± 0.001 mm, comprising 5.5 mm on main screw lead scale, 0.28 mm on screw rotation scale, and 0.003 mm added from vernier. Some micrometers are provided with a vernier scale on the sleeve in addition to the regular graduations. These permit measurements within 0.001 millimetre to be made on metric micrometers ...
There are two styles of small-hole gauges: full-ball and half-ball. The full-ball gauges are easier to set correctly and maintain, under the pressure of measurement, a better representation of the bore. Half-ball gauges tend to spring just a little bit, and this may be enough to make a measurement incorrect.
Although metering pumps can pump water, they are often used to pump chemicals, solutions, or other liquids. Many metering pumps are rated to be able to pump into a high discharge pressure. They are typically made to meter at flow rates which are practically constant (when averaged over time) within a wide range of discharge (outlet) pressure.
The pressure vessels can be either fired or unfired. [17] The pressure may be from external sources, or by the application of heating from an indirect or direct source as a result of a process, or any combination of the two. [18] The rules contained in this section can be used as an alternative to the minimum requirements specified in Division 1.