Search results
Results From The WOW.Com Content Network
1–2 mV Potential created at ambient temperatures from K Type Thermocouple: Centi-10 −2 ~10–50 mV Ripple voltage in the output of a good DC power supply [9] 75 mV Nerve cell resting potential [10] Deci-10 −1: 320 mV Typical voltage reference level in consumer audio electronics (0.316 V rms) [11] ~500 mV
100 dBμ or 100 mV/m: blanketing interference may occur on some receivers; 60 dBμ or 1.0 mV/m: frequently considered the edge of a radio station's protected area in North America; 40 dBμ or 0.1 mV/m: the minimum strength at which a station can be received with acceptable quality on most receivers
A digital current loop uses the absence of current for high (space or break), and the presence of current in the loop for low (mark). [1] This is done to ensure that on normal conditions there is always current flowing and in the event of a line being cut the flow stops indefinitely, immediately raising the alarm of the event usually as the heavy noise of the teleprinter not being synchronized ...
The resolution of a multimeter is the smallest part of the scale which can be shown, which is scale dependent. On some digital multimeters it can be configured, with higher resolution measurements taking longer to complete. For example, a multimeter that has a 1 mV resolution on a 10 V scale can show changes in measurements in 1 mV increments.
Historically the "conventional" volt, V 90, defined in 1987 by the 18th General Conference on Weights and Measures [3] and in use from 1990 to 2019, was implemented using the Josephson effect for exact frequency-to-voltage conversion, combined with the caesium frequency standard.
The voltage can reach 2 volts peak-to-peak with levels referenced to −10 dBV (300 mV) at 10 kΩ. The frequency response of most modern equipment is advertised as at least 20 Hz to 20 kHz, which corresponds to the range of human hearing. Line outputs are intended to drive a load impedance of 10,000 ohms; with only a few volts, this requires ...
where I C is the DC collector current at the Q-point, and V T is the thermal voltage, typically about 26 mV at room temperature. For a typical current of 10 mA , g m ≈ 385 mS . The input impedance is the current gain ( β ) divided by the transconductance.