Ads
related to: x86 32 bit interrupt return error fix windows 7pchelpsoft.com has been visited by 1M+ users in the past month
Search results
Results From The WOW.Com Content Network
Will change OperandSize from 16-bit to 32-bit if CS.D=0, or from 32-bit to 16-bit if CS.D=1. 67h: AddressSize override. Will change AddressSize from 16-bit to 32-bit if CS.D=0, or from 32-bit to 16-bit if CS.D=1. The 80386 also introduced the two new segment registers FS and GS as well as the x86 control, debug and test registers.
INT is an assembly language instruction for x86 processors that generates a software interrupt. It takes the interrupt number formatted as a byte value. [1] When written in assembly language, the instruction is written like this: INT X. where X is the software interrupt that should be generated (0-255).
Ralf Brown's Interrupt List (aka RBIL, x86 Interrupt List, MS-DOS Interrupt List or INTER) is a comprehensive list of interrupts, calls, hooks, interfaces, data structures, CMOS settings, memory and port addresses, as well as processor opcodes for x86 machines from the 1981 IBM PC up to 2000 (including many clones), [1] [2] [nb 1] most of it still applying to IBM PC compatibles today.
INT is an x86 instruction that triggers a software interrupt, and 13 hex is the interrupt number (as a hexadecimal value) being called. Modern computers come with both BIOS INT 13h and UEFI functionality that provides the same services and more, with the exception of UEFI Class 3 that completely removes CSM thus lacks INT 13h and other interrupts.
The descriptors may be either interrupt gates, trap gates or, for 32-bit protected mode only, task gates. Interrupt and trap gates point to a memory location containing code to execute by specifying both a segment (present in either the GDT or LDT) and an offset within that segment. The only difference between trap and interrupt gates is that ...
FLAGS registers can be moved from or to the stack. This is part of the job of saving and restoring CPU context, against a routine such as an interrupt service routine whose changes to registers should not be seen by the calling code. Here are the relevant instructions: The PUSHF and POPF instructions transfer the 16-bit FLAGS register.
While capable of encoding values from 8 to 31 (values 0 to 7 map to ModR/M-encoded variants of the older POP instruction, making them unusable for XOP), only maps 8, 9 and 0Ah were ever used: map 8 for instructions that take an 8-bit immediate, map 9 for instructions that don't take an immediate, and map 0Ah for instructions that take a 32-bit ...
Also, importantly, address offsets are 32-bit (instead of 16-bit), and the segment base in each segment descriptor is also 32-bit (instead of 24-bit). The general operation of the segmentation unit is otherwise unchanged. The paging unit may be enabled or disabled; if disabled, operation is the same as on the 80286.