The values of pH and HCO3 of venous blood are close enough to arterial blood for direct comparison. The pCO2 of venous blood is less reliably compared to arterial blood but may be used in some cases. The PO2 level of venous blood is always significantly lower that arterial and should be reported, labeled and interpreted as venous PO2. [21]
Arterial blood carbon dioxide tension. P a CO 2 – Partial pressure of carbon dioxide at sea level in arterial blood is between 35 and 45 mmHg (4.7 and 6.0 kPa). [9] Venous blood carbon dioxide tension. P v CO 2 – Partial pressure of carbon dioxide at sea level in venous blood is between 40 and 50 mmHg (5.33 and 6.67 kPa). [9]
Normal arterial blood oxygen saturation levels in humans are 96–100 percent. [1] If the level is below 90 percent, it is considered low and called hypoxemia . [ 2 ] Arterial blood oxygen levels below 80 percent may compromise organ function, such as the brain and heart, and should be promptly addressed.
Pulse oximetry is a noninvasive method for monitoring blood oxygen saturation. Peripheral oxygen saturation (SpO 2) readings are typically within 2% accuracy (within 4% accuracy in 95% of cases) of the more accurate (and invasive) reading of arterial oxygen saturation (SaO 2) from arterial blood gas analysis.
A blood gas test or blood gas analysis tests blood to measure blood gas tension values and blood pH.It also measures the level and base excess of bicarbonate.The source of the blood is reflected in the name of each test; arterial blood gases come from arteries, venous blood gases come from veins and capillary blood gases come from capillaries. [1]
An exception is for acid–base and blood gases, which are generally given for arterial blood. [citation needed] Still, the blood values are approximately equal between the arterial and venous sides for most substances, with the exception of acid–base, blood gases and drugs (used in therapeutic drug monitoring (TDM) assays). [6]
The alveolar oxygen partial pressure is lower than the atmospheric O 2 partial pressure for two reasons.. Firstly, as the air enters the lungs, it is humidified by the upper airway and thus the partial pressure of water vapour (47 mmHg) reduces the oxygen partial pressure to about 150 mmHg.
For F I O 2 values equal to or greater than 0.5, the alveolar–arterial gradient value should be used in the APACHE II score calculation. Otherwise, the PaO 2 will suffice. [4] The ratio between partial pressure of oxygen in arterial blood and F I O 2 is used as an indicator of hypoxemia per the American-European Consensus Conference on lung ...