Time-delay relay contacts must be specified not only as either normally open or normally closed, but whether the delay operates in the direction of closing or in the direction of opening. The following is a description of the four basic types of time-delay relay contacts. First, we have the normally open, timed-closed (NOTC) contact.
An electromagnetic relay with a pair of contacts. An electrical contact is an electrical circuit component found in electrical switches, relays, connectors and circuit breakers. [1] Each contact is a piece of electrically conductive material, typically metal.
Normally closed mercury relay, with coil around top of tube and adjustable angle. A mercury relay (mercury displacement relay, mercury contactor) is a relay that uses mercury as the switching element. They are used as high-current switches or contactors, where contact erosion from constant cycling would be a problem for conventional relay contacts.
All contacts associated with a device will change state when the device is energized. Figure 1 shows a typical relay logic diagram. In this circuit, a STOP/START station is used to control two pilot lights. When the START button is pressed, the control relay energizes and its associated contacts change state.
Today, microprocessor-based relays can perform many protective functions in one device. [1] When one device performs several protective functions, it is typically denoted "11" by the standard as a "Multifunction Device", but ANSI Device Numbers are still used in documentation like single-line diagrams or schematics to indicate which specific ...
Reed relays are used when operating currents are relatively low, and offer high operating speed, good performance with very small currents that are not reliably switched by conventional contacts, high reliability and long life. Millions of reed relays were used in telephone exchanges in the 1970s and 1980s.
A solid state relay (SSR) is an electronic switching device that switches on or off when an external voltage (AC or DC) is applied across its control terminals. They serve the same function as an electromechanical relay , but solid-state electronics contain no moving parts and have a longer operational lifetime.
from 2nd battery and 12/24 V relay: 31 return to battery- or direct to ground 31a return to battery- 12/24 V relay 31b return to battery- or ground through switch 85d 31c return to battery- 12/24 V relay 31, 31a Electric motors; 32 return 31 33 main terminal (swap of 32 and 33 is possible) 30 33a limit 33b field 54e 33f 2. slow rpm: 33g 3. slow ...