Ad
related to: fire sprinkler system symbols and meanings
Search results
Results From The WOW.Com Content Network
A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...
A fire sprinkler mounted on a ceiling. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year.
Deluge system Type of sprinkler system where sprinkler heads do not have individual valves, and the water (or other extinguishing agent) is disbursed from all sprinkler heads simultaneously when a central (or zoned) valve is triggered by a sensor (or manually). This is typically reserved for industrial areas where rapid fire spread must be ...
The National Fire Protection Association have a special labeling system in the standard for Health Care Facilities, such as hospitals and dentistry offices. This standard puts more emphasis on gases found in Medical gas supply systems , which consist of both oxidizing gases and gases that displace oxygen .
Residential sprinkler system: A sprinkler system arranged for fire suppression in a dwelling. Residual pressure: When a pumper is taking its water supply from a hydrant the engineer must make sure the pump is not taking every last bit of the pressure the hydrant is able to provide. Some residual pressure must be allowed to remain to provide a ...
Sprinkler systems installed by sprinkler fitters can include the underground supply as well as integrated overhead piping systems and standpipes. The fire suppression piping may contain water, air (in a dry system), antifreeze, gas or chemicals as in a hood system, or a mixture producing fire retardant foam. Sprinkler fitters work with a ...
ISO 7010 states on all symbols with a first aid cross, that it "may be replaced with another element appropriate to cultural requirements". In countries with a Muslim -majority population, an appropriate symbol is the crescent .
An Ansul fire suppression system in a hospital cafeteria. Fire suppression systems are used to extinguish, control, or in some cases, entirely prevent fires from spreading or occurring. Fire suppression systems have an incredibly large variety of applications, and as such, there are many different types of suppression systems for different ...