Ad
related to: best steam vent for radiator installation diagram 2 cycle tank
Search results
Results From The WOW.Com Content Network
Steam is diverted from the exhaust steam pipes into the water tanks via condensing pipes within the same tanks. [5] The water in the tanks could quickly heat up near boiling point, reducing the condensing effect on the exhaust steam. It was not unknown for the tanks to be emptied and refilled with cold water on a regular basis.
Collects steam at the top of the boiler (well above the water level) so that it can be fed to the engine via the main steam pipe, or dry pipe, and the regulator/throttle valve. [2] [5] [6]: 211–212 [3]: 26 Air pump / Air compressor Westinghouse pump (US+) Powered by steam, it compresses air for operating the train air brake system.
In a steam heating system, each room is equipped with a radiator which is connected to a source of low-pressure steam (a boiler). Steam entering the radiator condenses and gives up its latent heat, returning to liquid water. The radiator in turn heats the air of the room, and provides some direct radiant heat. The condensate water returns to ...
As well, steam locomotive exhaust systems typically vent cylinder steam exhaust through the chimney, to enhance the draught through the boiler. Chimneys are designed to carry the exhaust steam and smoke clear of the driver's line of sight while remaining short enough to clear overhead structures. Some chimneys included apparatus to suppress the ...
The North American P-51 Mustang makes significant use of the Meredith effect in its belly radiator design. [1]The Meredith effect is a phenomenon whereby the aerodynamic drag produced by a cooling radiator may be offset by careful design of the cooling duct such that useful thrust is produced by the expansion of the hot air in the duct.
The valves are normally installed with the first installation of a system, then remain in place for the life of the system. They are generally reliable and require no maintenance. If they do eventually fail, they are replaced rather than repaired. A leaking valve commonly shows a dribble of water from the air vent, or stains of rust or limescale.
In one case, a 2,600 US gallons per minute (160 L/s) steam condensate pump exploded when it was operated with its suction and discharge valves closed. The force of the explosion was such that it propelled a 5-pound (2.3 kg) piece of metal casing over 400 feet (120 m) away from the site of the explosion. [2]
This scrubbing (or stripping) steam is fed to the bottom of the deaeration section of the deaerator. When steam contacts the feedwater, it heats it up to its boiling point and dissolved gases are released from the feedwater and vented from the deaerator through the vent. The treated water falls into a storage tank below the deaerator. [20] [3]