When.com Web Search

  1. Ads

    related to: motor starting torque calculation sheet sample pdf file one page free lease agreements to print

Search results

  1. Results From The WOW.Com Content Network
  2. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    is the motor torque constant (SI unit, newton–metre per ampere, N·m/A), see below If two motors with the same K v {\displaystyle K_{\text{v}}} and torque work in tandem, with rigidly connected shafts, the K v {\displaystyle K_{\text{v}}} of the system is still the same assuming a parallel electrical connection.

  3. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage , power factor on short circuit, total leakage reactance , and starting torque of the motor can be found.

  4. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque. One basic method to reduce the starting current is with a reduced voltage autotransformer with taps at 50%, 65% and 80% of the applied line voltage; once the motor is started the ...

  5. Motor soft starter - Wikipedia

    en.wikipedia.org/wiki/Motor_soft_starter

    A motor soft starter is a device used with AC electrical motors to temporarily reduce the load and torque in the powertrain and electric current surge of the motor during start-up. This reduces the mechanical stress on the motor and shaft, as well as the electrodynamic stresses on the attached power cables and electrical distribution network ...

  6. Squirrel-cage rotor - Wikipedia

    en.wikipedia.org/wiki/Squirrel-cage_rotor

    By adjusting the shape of the bars in the rotor, the speed-torque characteristics of the motor can be changed, to minimize starting current or to maximize low-speed torque, for example. Squirrel-cage induction motors are very prevalent in industry, in sizes from below 1 kilowatt (1.3 hp) up to tens of megawatts (tens-of-thousand horsepower).

  7. Shaded-pole motor - Wikipedia

    en.wikipedia.org/wiki/Shaded-pole_motor

    The shaded-pole motor is the original type of AC single-phase electric motor, dating back to at least as early as 1890. [1] A shaded-pole motor is a motor, in which the auxiliary winding is composed of a copper ring or bar surrounding a portion of each pole to produce a weakly rotating magnetic field. [2]

  8. Repulsion motor - Wikipedia

    en.wikipedia.org/wiki/Repulsion_motor

    If the brushes are shifted counter-clockwise from the main magnetic axis, the motor will rotate in a counter-clockwise direction. Torque and speed control. The starting torque of a repulsion motor is determined by the angle of brush shift from the main magnetic axis. The maximum torque is obtained from a brush shift of 45 degrees.

  9. Direct torque control - Wikipedia

    en.wikipedia.org/wiki/Direct_torque_control

    Direct torque control (DTC) is one method used in variable-frequency drives to control the torque (and thus finally the speed) of three-phase AC electric motors.This involves calculating an estimate of the motor's magnetic flux and torque based on the measured voltage and current of the motor.

  1. Related searches motor starting torque calculation sheet sample pdf file one page free lease agreements to print

    motor size constantmotor constants formula
    motor constants chartmotor constants explained