When.com Web Search

  1. Ads

    related to: 1 hour fire rated caulking hilti concrete mix home depot

Search results

  1. Results From The WOW.Com Content Network
  2. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    They receive a fire rating by combining materials in an arrangement specific to the item (a pipe or cable, for example) penetrating the fire-rated wall or floor and the construction arrangement of the fire-rated wall or floor. A two-hour-rated pipe-penetration firestop may consist of a layer of caulking over packed mineral wool. The arrangement ...

  3. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    A building under construction, showing the structurally independent cinderblock firewalls subdividing the building Building 4 of the Waynesboro Outlet Village, showing a concrete firewall running through the building Concrete firewalls still standing on Building 7 of the former Waynesboro Outlet Village, following a firefighter training exercise which intentionally burned the building

  4. Caulk - Wikipedia

    en.wikipedia.org/wiki/Caulk

    Caulk (also known as caulking and calking) [1] is a material used to seal joints or seams against leakage in various structures and piping. The oldest form of caulk consisted of fibrous materials driven into the wedge-shaped seams between boards on wooden boats or ships. Cast iron sewerage pipes were formerly caulked in a similar way.

  5. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    This rating is the requirement in data safes and vault structures for protecting digital information on magnetic media or hard drives. Temperatures inside the protected chamber must be held below 125 °F (52 °C) for the time period specified, such as Class 125-2 Hour, with temperatures up to 2,000 °F (1,090 °C) outside the vault.

  6. Sealant - Wikipedia

    en.wikipedia.org/wiki/Sealant

    Self-leveling silicone firestop system used around pipe through-penetration in a two-hour fire-resistance rated concrete floor assembly. Sealant is a substance used to block the passage of fluids through openings in materials, [1] a type of mechanical seal. In building construction sealant is sometimes synonymous with caulk (especially if ...

  7. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Canada de-rates closures, where, for instance a 2-hour closure is acceptable for use in a 3-hour fire separation, so long as the fire separation is not an occupancy separation or firewall. The lowered rating is then referred to as a fire protection rating, both for firestops, unless they contain plastic pipes and regular closures. Firestops