When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering.A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria. [1]

  3. Structural load - Wikipedia

    en.wikipedia.org/wiki/Structural_load

    For example, in designing a staircase, a dead load factor may be 1.2 times the weight of the structure, and a live load factor may be 1.6 times the maximum expected live load. These two "factored loads" are combined (added) to determine the "required strength" of the staircase. The size of the load factor is based on the probability of ...

  4. Permissible stress design - Wikipedia

    en.wikipedia.org/wiki/Permissible_stress_design

    Such loads may include pressure thrusts and the weight of materials. The predicted stresses and deflections are compared with allowable values that have a "factor" against various failure mechanisms such as leakage, yield, ultimate load prior to plastic failure, buckling, brittle fracture, fatigue, and vibration/harmonic effects.

  5. Structural engineering theory - Wikipedia

    en.wikipedia.org/wiki/Structural_engineering_theory

    A load case is a combination of different types of loads with safety factors applied to them. A structure is checked for strength and serviceability against all the load cases it is likely to experience during its lifetime. Typical load cases for design for strength (ultimate load cases; ULS) are: 1.2 x Dead Load + 1.6 x Live Load

  6. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  7. Euler's critical load - Wikipedia

    en.wikipedia.org/wiki/Euler's_critical_load

    The critical load is the greatest load that will not cause lateral deflection (buckling). For loads greater than the critical load, the column will deflect laterally. The critical load puts the column in a state of unstable equilibrium. A load beyond the critical load causes the column to fail by buckling. As the load is increased beyond the ...

  8. I tried Factor meal delivery for a week — here’s why I’m hooked

    www.aol.com/news/factor-meal-delivery-review...

    I tried Factor’s pre-made meal delivery service for a week to help make meal planning at home easier and stress-free. Here’s what I thought about the service’s ready-to-eat meals.

  9. Ultimate load - Wikipedia

    en.wikipedia.org/wiki/Ultimate_load

    In engineering, the ultimate load [1] is a statistical figure used in calculations, and should (hopefully) never actually occur. Strength requirements are specified in terms of limit loads (the maximum loads to be expected in service) and ultimate loads (limit loads multiplied by prescribed factors of safety).