Google data centers are the large data center facilities Google uses to provide their services, which combine large drives, computer nodes organized in aisles of racks, internal and external networking, environmental controls (mainly cooling and humidification control), and operations software (especially as concerns load balancing and fault tolerance).
In 2012 Google published a photo gallery that shows the design of its cooling system, followed by an explanation of Data Center Vice President Joseph Kava, of how it works. In the data center shown the rooms serve as cold corridors, there is a raised floor but there are no perforated tiles. Cooling occurs in closed corridors with rows of racks ...
In 2016, Google joined the project and published the designs of its 48V DC shallow data center rack. This design had long been part of Google data centers. By eliminating the multiple transformers usually deployed in data centers, Google had achieved a 30% increase in energy efficiency. [96]
The industry-standard rack cabinet is 42U tall; [1] however, many data centers have racks taller than this. [2] The term relay rack appeared first in the world of telephony. [3] By 1911, the term was also being used in railroad signaling. [4] There is little evidence that the dimensions of these early racks were standardized. Telephone ...
The Open Compute Project (OCP) is an organization that facilitates the sharing of data center product designs and industry best practices among companies. [1] [2] Founded in 2011, OCP has significantly influenced the design and operation of large-scale computing facilities worldwide.
The tensor processing unit was announced in May 2016 at Google I/O, when the company said that the TPU had already been used inside their data centers for over a year. [5] [4] Google's 2017 paper describing its creation cites previous systolic matrix multipliers of similar architecture built in the 1990s. [8]
The choice of racks in a server room is usually the prime factor when determining space. Many organisations use telco racks or enclosed cabinets to make the most of the space they have. Today, with servers that are one-rack-unit (1U) high and new blade servers, a single 19- or 23-inch rack can accommodate anywhere from 42 to hundreds of servers.
Pages in category "Data centers" ... Google data centers; Green data center; H. ... Rack unit; S. Software-defined data center;