Mass spectrometry data analysis is specific to the type of experiment producing the data. General subdivisions of data are fundamental to understanding any data. Many mass spectrometers work in either negative ion mode or positive ion mode. It is very important to know whether the observed ions are negatively or positively charged.
Schematic of field desorption ionization with emitter at left and mass spectrometer at right. Field desorption (FD) is a method of ion formation used in mass spectrometry (MS) in which a high-potential electric field is applied to an emitter with a sharp surface, such as a razor blade, or more commonly, a filament from which tiny "whiskers" have formed.
Plasma desorption ionization mass spectrometry (PDMS), also called fission fragment ionization, is a mass spectrometry technique in which ionization of material in a solid sample is accomplished by bombarding it with ionic or neutral atoms formed as a result of the nuclear fission of a suitable nuclide, typically the californium isotope 252 Cf ...
The x-axis of a mass spectrum represents a relationship between the mass of a given ion and the number of elementary charges that it carries. This is written as the IUPAC standard m/z to denote the quantity formed by dividing the mass of an ion (in daltons) by the dalton unit and by its charge number (positive absolute value).
In the selected ion flow tube mass spectrometer, SIFT-MS, ions are generated in a microwave plasma ion source, usually from a mixture of laboratory air and water vapor. . From the formed plasma, a single ionic species is selected using a quadrupole mass filter to act as "precursor ions" (also frequently referred to as primary or reagent ions in SIFT-MS and other processes involving chemical ...
The mass spectrometry analysis, however, takes place at high vacuum condition. Therefore, ions entering the mass spectrometer, first go through a source - to - analyzer interface (vacuum interface), which was designed in order to bridge the atmospheric pressure region to the mass spectrometer vacuum. It also minimizes spectrometer contamination.
A schematic diagram of chemical ionization source. Chemical ionization (CI) is a soft ionization technique used in mass spectrometry. [1] [2] This was first introduced by Burnaby Munson and Frank H. Field in 1966. [3]
A reflectron (mass reflectron) is a type of time-of-flight mass spectrometer (TOF MS) that comprises a pulsed ion source, field-free region, ion mirror, and ion detector and uses a static or time dependent electric field in the ion mirror to reverse the direction of travel of the ions entering it.