When.com Web Search

  1. Ads

    related to: radiation heat loss calculator residential construction contractors near 22406 zip code

Search results

  1. Results From The WOW.Com Content Network
  2. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: = Where: = rate of heat transfer [W] = heat transfer surface area [m 2]

  3. Passive daytime radiative cooling - Wikipedia

    en.wikipedia.org/wiki/Passive_daytime_radiative...

    [7] [8] [91] A multilayer PDRC surface covering 10% of a building's roof can replace 35% of air conditioning used during the hottest hours of daytime. [7] In suburban single-family residential areas, PDRCs can lower energy costs by 26% to 46% in the United States [90] and lower temperatures on average by 5.1ᵒC. With the addition of "cold ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  5. Balance point temperature - Wikipedia

    en.wikipedia.org/wiki/Balance_point_temperature

    The building balance point temperature is the outdoor air temperature when the heat gains of the building are equal to the heat losses. [1] Internal heat sources due to electric lighting, mechanical equipment, body heat, and solar radiation may offset the need for additional heating although the outdoor temperature may be below the thermostat set-point temperature.

  6. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  7. California pushes heat pumps for all new homes starting 2026 ...

    www.aol.com/news/california-pushes-heat-pumps...

    New homes built in California are more likely to have all-electric appliances starting in 2026 after energy regulators approved new state building standards Wednesday that encourage adoption of ...