When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  4. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    The design does not allow for fitting of RCDs or RCBOs. Some Wylex standard models were made with an RCD instead of the main switch, but (for consumer units supplying the entire installation) this is no longer compliant with the wiring regulations as alarm systems should not be RCD-protected. There are two styles of fuse base that can be ...

  5. Electrical wiring in the United Kingdom - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_the...

    Within a consumer unit RCD protection may be found in the form of either RCBOs (residual current circuit breakers with overcurrent protection) which combine MCB and RCD technology, or a 'split-way' arrangement in which one or more RCCBs each protect a subset of MCBs that need RCD protection. Reductions in the cost of devices and the principle ...

  6. Ring circuit - Wikipedia

    en.wikipedia.org/wiki/Ring_circuit

    Consumer unit is at bottom left. The ring starts at the consumer unit (also known as fuse box, distribution board, or breaker box), visits each socket in turn, and then returns to the consumer unit. The ring is fed from a fuse or circuit breaker in the consumer unit.

  7. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    The DIN-rail-mounted thermal-magnetic miniature circuit breaker is the most common style in modern domestic consumer units and commercial electrical distribution boards throughout Europe. The design includes the following components: Actuator lever – used to manually trip and reset the circuit breaker. Also indicates the status of the circuit ...

  8. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated:

  9. BS 7671 - Wikipedia

    en.wikipedia.org/wiki/BS_7671

    Amendment 3 introduced requirements for the use of non-combustable consumer units (or enclosures) in domestic premises, along with use of metal wiring/containment clips in certain situations, and expanded use of RCDs into commercial/industrial spaces. [12]