Search results
Results From The WOW.Com Content Network
Vernier caliper scales; main at top, vernier at bottom. It reads 3.58 ± 0.02 mm by adding 3.00 mm (left red mark) on the fixed main scale to vernier 0.58 mm (right red mark). The main scale reading is that to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales.
The main scale reading is the rightmost graduation that is to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales. The 0.02 mm engraving indicates the caliper's accuracy and is the "Vernier constant" for this scale. He was born in Ornans, France, in 1580. He was ...
The dieter's problem: this scale can only resolve weight changes of 0.2 lbs, even though the digital display looks as if it could show 0.1 In the science of measurement , the least count of a measuring instrument is the smallest value in the measured quantity that can be resolved on the instrument's scale. [ 1 ]
The calipers in the diagram show a primary reading on the metric scale of about 2.475 cm (2.4 cm read from the main scale plus about 0.075 cm from the vernier scale). Calipers often have a "zero point error": meaning that the calipers do not read 0.000 cm when the jaws are closed.
Vernier acuity (from the term "vernier scale", named after astronomer Pierre Vernier) is a type of visual acuity – more precisely of hyperacuity – that measures the ability to discern a disalignment among two line segments or gratings. A subject's vernier (IPA: / ˈ v ɜːr n ɪər /) acuity is the smallest visible offset between the ...
The rod may be equipped with a target to increase the readable range of the rod. When the target is equipped with a Vernier scale measurements to the thousandths of a foot are possible. For readings less than 7 ft the target is attached on the bottom section of the rod and adjust by signals from level operator until the target is inline with ...
Vernier micrometer reading 5.783 ± 0.001 mm, comprising 5.5 mm on main screw lead scale, 0.28 mm on screw rotation scale, and 0.003 mm added from vernier. Some micrometers are provided with a vernier scale on the sleeve in addition to the regular graduations. These permit measurements within 0.001 millimetre to be made on metric micrometers ...
The left height gauge has the vernier scale, while the right one is an electronic height gauge with a digital readout. A height gauge is a measuring device used for determining the height of objects, and for marking of items to be worked on.