  2. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]

  3. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Using metric units, the volumetric flow rate of a nozzle is given by =, [1] [2] where q is the flow rate in litres per minute ( l/min ), p is the pressure at the nozzle in bar and K is the K-factor is given in units of (/) /.

  4. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  5. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    A jockey pump is sized for a flow less than one sprinkler in order to ensure a system pressure drop significant enough to start the main fire pump. Jockey pumps are typically small multistage centrifugal pumps, and do not have to be listed or certified for fire system application. The control equipment for jockey pumps may however carry approvals.

  6. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...

  7. Irrigation sprinkler - Wikipedia

    en.wikipedia.org/wiki/Irrigation_sprinkler

    These sprinklers can be fixed spray heads that have a set pattern and generally spray between 1.5 and 2 m (5 and 7 ft), full rotating sprinklers that can spray a broken stream of water from 6 to 12 m (20 to 40 ft), or small drip emitters that release a slow, steady drip of water on more delicate plants such as flowers and shrubs.

  1. Related searches sprinklers not enough pressure to pump 2 1/2 2 1 2 horsepower outboard

    fire sprinkler headssprinklers not enough pressure to pump 2 1/2 2 1 2 horsepower outboard motors
    fire sprinkler system diagram