When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Oxygen sensor - Wikipedia

    en.wikipedia.org/wiki/Oxygen_sensor

    The type of oxygen sensor used in most underwater diving applications is the electro-galvanic oxygen sensor, a type of fuel cell, which is sometimes called an oxygen analyser or ppO 2 meter. They are used to measure the oxygen concentration of breathing gas mixes such as nitrox and trimix . [ 9 ]

  3. Pulse oximetry - Wikipedia

    en.wikipedia.org/wiki/Pulse_oximetry

    Pulse oximetry is a noninvasive method for monitoring blood oxygen saturation. Peripheral oxygen saturation (SpO 2) readings are typically within 2% accuracy (within 4% accuracy in 95% of cases) of the more accurate (and invasive) reading of arterial oxygen saturation (SaO 2) from arterial blood gas analysis.

  4. Electro-galvanic oxygen sensor - Wikipedia

    en.wikipedia.org/wiki/Electro-galvanic_oxygen_sensor

    The oxygen content of a stored gas mixture can be analysed by passing a small flow of the gas over a recently calibrated cell for long enough that the output stabilises. The stable output represents the fraction of oxygen in the mixture. Care must be taken to ensure that the gas flow is not diluted by ambient air, as this would affect the reading.

  5. Clark electrode - Wikipedia

    en.wikipedia.org/wiki/Clark_electrode

    The Clark oxygen electrode laid the basis for the first glucose biosensor (in fact the first biosensor of any type), invented by Clark and Lyons in 1962. [6] This sensor used a single Clark oxygen electrode coupled with a counter-electrode. As with the Clark electrode, a permselective membrane covers the Pt electrode.

  6. Transcutaneous oxygen measurement - Wikipedia

    en.wikipedia.org/wiki/Transcutaneous_oxygen...

    To perform the test, one set of electrodes are placed on viable tissue (e.g. the chest) as a control and a second set is placed around the tissue in question (e.g. legs or feet). The electrodes may mildly heat the skin to increase blood flow into the area. Oxygen may also be given to the patient to see if that increases oxygen levels in the tissue.

  7. File:% oxygen saturation vs depth.pdf - Wikipedia

    en.wikipedia.org/wiki/File:%_oxygen_saturation_vs...

    You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.

  8. MAP sensor - Wikipedia

    en.wikipedia.org/wiki/MAP_sensor

    It is a one-to-one relationship with an offset of -100 kPa for boost pressure. Thus, a MAP sensor will always read 100 kPa more than a boost sensor measuring the same conditions. A MAP sensor will never display a negative reading because it is measuring absolute pressure, where zero is the total absence of pressure.

  9. Fraction of inspired oxygen - Wikipedia

    en.wikipedia.org/wiki/Fraction_of_Inspired_Oxygen

    Fraction of inspired oxygen (F I O 2), correctly denoted with a capital I, [1] is the molar or volumetric fraction of oxygen in the inhaled gas. Medical patients experiencing difficulty breathing are provided with oxygen-enriched air, which means a higher-than-atmospheric F I O 2. Natural air includes 21% oxygen, which is equivalent to F I O 2 ...