Search results
Results From The WOW.Com Content Network
A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.
Double pipe heat exchanger Fixed straight tubes heat exchanger: U-shaped tubes heat exchanger Spiral heat exchanger Covered gas vent Curved gas vent Air filter: Funnel or tundish: Steam trap: Viewing glass Pressure reducing valve: Valve: Gate valve: Control valve: Manual valve Check valve: Needle valve: Butterfly valve: Diaphragm valve: Ball ...
Pipe rams close around a drill pipe, restricting flow in the annulus (ring-shaped space between concentric objects) between the outside of the drill pipe and the wellbore, but do not obstruct flow within the drill pipe. Variable-bore pipe rams can accommodate tubing in a wider range of outside diameters than standard pipe rams, but typically ...
An exploded-view drawing is a diagram, picture, schematic or technical drawing of an object, that shows the relationship or order of assembly of various parts. [1]It shows the components of an object slightly separated by distance, or suspended in surrounding space in the case of a three-dimensional exploded diagram.
An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.
Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become flooded. An example of where backflow would harm the water supply is the use of well washing devices inside underground sewerage pumping stations.
A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.
The set of drawing of each system like water supply, drainage etc is consist of Plans, Riser diagram, Installation details, Legends, Notes. Every pipes should me marked with pipe sizes. If the drawing is detailed, fixture units also should be marked along with the pipe.