When.com Web Search

  1. Ads

    related to: unfactored load calculation

Search results

  1. Results From The WOW.Com Content Network
  2. Structural load - Wikipedia

    en.wikipedia.org/wiki/Structural_load

    Dead loads have small load factors, such as 1.2, because weight is mostly known and accounted for, such as structural members, architectural elements and finishes, large pieces of mechanical, electrical and plumbing (MEP) equipment, and for buildings, it's common to include a Super Imposed Dead Load (SIDL) of around 5 pounds per square foot ...

  3. Limit state design - Wikipedia

    en.wikipedia.org/wiki/Limit_state_design

    Limit State Design (LSD), also known as Load And Resistance Factor Design (LRFD), refers to a design method used in structural engineering. A limit state is a condition of a structure beyond which it no longer fulfills the relevant design criteria. [ 1 ]

  4. Permissible stress design - Wikipedia

    en.wikipedia.org/wiki/Permissible_stress_design

    Such loads may include pressure thrusts and the weight of materials. The predicted stresses and deflections are compared with allowable values that have a "factor" against various failure mechanisms such as leakage, yield, ultimate load prior to plastic failure, buckling, brittle fracture, fatigue, and vibration/harmonic effects.

  5. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  6. Eurocode 1: Actions on structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_1:_Actions_on...

    In the Eurocode series of European standards (EN) related to construction, Eurocode 1: Actions on structures (abbreviated EN 1991 or, informally, EC 1) describes how to design load-bearing structures. It includes characteristic values for various types of loads and densities for all materials which are likely to be used in construction.

  7. Limit load (physics) - Wikipedia

    en.wikipedia.org/wiki/Limit_load_(physics)

    Any load above the limit load will lead to the formation of plastic hinge in the structure. Engineers use limit states to define and check a structure's performance. Bounding Theorems of Plastic-Limit Load Analysis: Plastic limit theorems provide a way to calculate limit loads without having to solve the boundary value problem in continuum ...

  8. Macaulay's method - Wikipedia

    en.wikipedia.org/wiki/Macaulay's_method

    Using these integration rules makes the calculation of the deflection of Euler-Bernoulli beams simple in situations where there are multiple point loads and point moments. The Macaulay method predates more sophisticated concepts such as Dirac delta functions and step functions but achieves the same outcomes for beam problems.

  9. Ultimate load - Wikipedia

    en.wikipedia.org/wiki/Ultimate_load

    In engineering, the ultimate load [1] is a statistical figure used in calculations, and should (hopefully) never actually occur.. Strength requirements are specified in terms of limit loads (the maximum loads to be expected in service) and ultimate loads (limit loads multiplied by prescribed factors of safety).