When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Arc fault - Wikipedia

    en.wikipedia.org/wiki/Arc_fault

    Two types of wiring protection are standard thermal breakers and arc fault circuit breakers. Thermal breakers require an overload condition long enough that a heating element in the breaker trips the breaker off. In contrast, arc fault circuit breakers use magnetic or other means to detect increases in current draw much more quickly.

  3. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    An arc-fault circuit interrupter (AFCI) or arc-fault detection device (AFDD) [1] is a circuit breaker that breaks the circuit when it detects the electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.

  4. Arc flash - Wikipedia

    en.wikipedia.org/wiki/Arc_flash

    The circuit breaker closest to the downstream fault will send a restraining signal to prevent upstream breakers from tripping instantaneously. The presence of the fault will nevertheless activate the preset trip delay timer(s) of the upstream circuit breaker(s); this will allow an upstream circuit breaker to interrupt the fault, if still ...

  5. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Additionally, zones possess the following features: zones overlap, overlap regions denote circuit breakers, and all circuit breakers in a given zone with a fault will open in order to isolate the fault. Overlapped regions are created by two sets of instrument transformers and relays for each circuit breaker.

  6. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaking

    Arc-fault circuit interrupter (AFCI) or arc-fault detection device (AFDD) — detects electric arcs from the likes of loose wires. Recloser — A type of circuit breaker that closes automatically after a delay. These are used on overhead electric power distribution systems, to prevent short duration faults from causing sustained outages.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. ANSI device numbers - Wikipedia

    en.wikipedia.org/wiki/ANSI_device_numbers

    In electric power systems and industrial automation, ANSI Device Numbers can be used to identify equipment and devices in a system such as relays, circuit breakers, or instruments. The device numbers are enumerated in ANSI / IEEE Standard C37.2 Standard for Electrical Power System Device Function Numbers, Acronyms, and Contact Designations .

  9. Codebreaker (video game) - Wikipedia

    en.wikipedia.org/wiki/Codebreaker_(video_game)

    Codebreaker is a video game released in 1978 by Atari, Inc. for the Atari VCS (later renamed the Atari 2600). [1] It was in the first wave of Atari VCS games to follow the original nine launch titles.