When.com Web Search

  1. Ad

    related to: diagram of an ftir of 2

Search results

  1. Results From The WOW.Com Content Network
  2. Fourier-transform infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fourier-transform_infrared...

    Schematic diagram of a Michelson interferometer, configured for FTIR. In a Michelson interferometer adapted for FTIR, light from the polychromatic infrared source, approximately a black-body radiator, is collimated and directed to a beam splitter. Ideally 50% of the light is refracted towards the fixed mirror and 50% is transmitted towards the ...

  3. Two-dimensional infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Two-dimensional_infrared...

    Two-dimensional infrared spectroscopy (2D IR) is a nonlinear infrared spectroscopy technique that has the ability to correlate vibrational modes in condensed-phase systems. This technique provides information beyond linear infrared spectra, by spreading the vibrational information along multiple axes, yielding a frequency correlation spectrum.

  4. Geology applications of Fourier transform infrared spectroscopy

    en.wikipedia.org/wiki/Geology_applications_of...

    Schematic diagram Transmission FTIR: Transmission mode is the most widely used FTIR technique in geoscience due to its high analysis speed and cost-efficient characteristics. [4] The sample, either a rock or a mineral, is cut into a block and polished on both sides until a thin (typically 300 to 15 μm) wafer is created.

  5. Infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Infrared_spectroscopy

    Nonlinear two-dimensional infrared spectroscopy [48] [49] is the infrared version of correlation spectroscopy. Nonlinear two-dimensional infrared spectroscopy is a technique that has become available with the development of femtosecond infrared laser pulses. In this experiment, first a set of pump pulses is applied to the sample.

  6. Fourier-transform spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fourier-transform_spectroscopy

    The peak at the center is the ZPD position ("zero path difference"): Here, all the light passes through the interferometer because its two arms have equal length. The method of Fourier-transform spectroscopy can also be used for absorption spectroscopy. The primary example is "FTIR Spectroscopy", a common technique in chemistry.

  7. Infrared spectroscopy correlation table - Wikipedia

    en.wikipedia.org/wiki/Infrared_spectroscopy...

    cis-1,2-disub. alkenes 1660 medium trans-1,2-disub. alkenes 1675 medium trisub., tetrasub. alkenes 1670 weak conjugated C═C dienes 1600 strong 1650 strong with benzene ring 1625 strong with C═O 1600 strong C═C (both sp 2) any 1640–1680 medium aromatic C═C any 1450 weak to strong (usually 3 or 4) 1500 1580 1600 C≡C terminal alkynes

  8. Spectral line shape - Wikipedia

    en.wikipedia.org/wiki/Spectral_line_shape

    For example, if the heights of two lines are found to be h 1 and h 2, c 1 = h 1 / ε 1 and c 2 = h 2 / ε 2. [14] Parameters of the line shape are unknown. The intensity of each component is a function of at least 3 parameters, position, height and half-width. In addition one or both of the line shape function and baseline function may not be ...

  9. Nano-FTIR - Wikipedia

    en.wikipedia.org/wiki/Nano-FTIR

    The schematic representation of a nano-FTIR system with a broadband infrared source. Nano-FTIR (nanoscale Fourier transform infrared spectroscopy) is a scanning probe technique that utilizes as a combination of two techniques: Fourier transform infrared spectroscopy (FTIR) and scattering-type scanning near-field optical microscopy (s-SNOM).